Product Categories
Chassis and Wall Mounted Options
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
IEXT IEHR |
70W 150W |
11-16VDC 21-60VDC 60-132VDC |
♦12VDC ♦24VDC ♦36VDC ♦48VDC (other voltages on request) |
♦ Isolated input- output ♦ Overvoltage protection (IEXT) ♦ Short circuit protection ♦ Reverse input protection ♦ External trim pot for voltage adjustment
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
HFBC30 | 33W | 16.8VDC - 137.5VDC | ♦ 5.1VDC& 12VDC |
♦ Ultra wide input range ♦ Two outputs ♦ Overtemperature shutdown ♦ Short circuit protection ♦ Open frame - unenclosed ♦ Acc. to EN50155 railways standard
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
HFBC60 | 60W | 16.8-138VDC | ♦ 5.1VDC& 12VDC ♦ 24VDC |
♦ Ultra wide input range ♦ One or two outputs ♦ Overtemperature shutdown ♦ Short circuit protection ♦ Open frame - unenclosed ♦ Acc. to EN50155 railways standard
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
DCW100R |
100W | 14.4-34VDC 22-51VDC 29-67VDC 43-101VDC 58-135VDC 66-154VDC |
♦12VDC ♦24VDC ♦48VDC ♦110VDC |
♦ Designed to rail standards EN50155 & EN50121 ♦ Rugged design for on-board train applications ♦ Wide input voltage range ♦ Convection / Conduction cooled: No fans ♦ Fully isolated input – output 3000VDC ♦ Over voltage protection ♦ Overload and short circuit protection
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
DCW152R |
150W | 14.4-34VDC 22-51VDC 29-67VDC 43-101VDC 58-135VDC 66-154VDC |
♦ 5-48VDC, 8A max ♦ 5-24VDC, 4A max |
♦ Designed to rail standards EN50155 & EN50121 ♦ Rugged design for on-board train applications ♦ Wide input voltage range ♦ Convection / Conduction cooled: No fans ♦ Fully isolated input – output 3000VDC ♦ Over voltage protection ♦ Overload and short circuit protection
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP236R |
200W | 15-34VDC 22-51VDC 29-67VDC 42-101VDC 58-135VDC 66-154VDC |
♦12VDC ♦24VDC ♦48VDC ♦110VDC |
♦ Designed to rail standards EN50155 & EN50121 ♦ Wide input range ♦ Rugged design for on-board train applications ♦ Convection cooled: No fans ♦ Fully isolated input – output 3000VDC ♦ Over voltage protection ♦ Overload and short circuit protection
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
RWY | 30W 60W 100W 150W 200W 250W 280W |
17-30VDC 50-90VDC 77-137VDC |
♦ 12V ♦ 24V ♦ 5-72V (dual output models) |
♦ Designed to rail standards EN50155 and EN50121 ♦ Fully potted with thermally conductive MIL-spec silicon rubber compound ♦ Rugged design for on-board train applications ♦ Wide input voltage range ♦ Convection/Conduction cooled. No fans ♦ Fully isolated input - output 3000VDC ♦ Over voltage protection ♦ Overload and short circuit protection ♦ MTBF >150,000 hours ♦ Single and dual output options
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP65R |
300W | 15-34VDC 22-51VDC 29-67VDC 42-101VDC 58-135VDC 66-154VDC |
♦12VDC ♦24VDC ♦48VDC ♦110VDC |
• Designed to rail standards EN50155 & EN50121 • Wide input range • Rugged design for on-board train applications • Convection cooled: No fans • Fully isolated input – output 3000VDC • Over voltage protection • Overload and short circuit protection
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP319R |
500W | 15-34VDC 22-51VDC 29-67VDC 42-101VDC 58-135VDC 66-154VDC |
♦24VDC ♦48VDC ♦110VDC |